Slot: Indoor or Outdoor Regime (indoor_outdoor)
Indoor / outdoor regime. Mandatory for WBGT (the indoor vs outdoor distinction changes the equation and the health interpretation).
Tier: conditionally_core
Why this slot matters
Indoor and outdoor WBGT use different equations and carry different health interpretations; an indoor formula applied to outdoor conditions (or a regime left unstated) makes the value invalid or uninterpretable for the exposure being claimed.
In plain terms
Heat stress works differently inside and outside — indoors there is no direct sun and little wind — so heat metrics come in indoor and outdoor versions, and you need to know which one you are looking at.
URI: envar:slot/indoor_outdoor
Applicable Classes
| Name |
Description |
Modifies Slot |
| DerivedHeatMetric |
Methodology slots specific to derived heat metrics (WBGT, Heat Index, UTCI, a... |
yes |
Properties
Type and Range
Cardinality and Requirements
Examples
See Also
Annotations
| property |
value |
| tier |
conditionally_core |
| justification |
Indoor and outdoor WBGT use different equations and carry different health interpretations; an indoor formula applied to outdoor conditions (or a regime left unstated) makes the value invalid or uninterpretable for the exposure being claimed. |
| explanation |
Heat stress works differently inside and outside — indoors there is no direct sun and little wind — so heat metrics come in indoor and outdoor versions, and you need to know which one you are looking at. |
Schema Source
Mappings
| Mapping Type |
Mapped Value |
| self |
envar:indoor_outdoor |
| native |
envar:indoor_outdoor |
LinkML Source
name: indoor_outdoor
annotations:
tier:
tag: tier
value: conditionally_core
justification:
tag: justification
value: Indoor and outdoor WBGT use different equations and carry different health
interpretations; an indoor formula applied to outdoor conditions (or a regime
left unstated) makes the value invalid or uninterpretable for the exposure being
claimed.
explanation:
tag: explanation
value: Heat stress works differently inside and outside — indoors there is no
direct sun and little wind — so heat metrics come in indoor and outdoor versions,
and you need to know which one you are looking at.
description: Indoor / outdoor regime. Mandatory for WBGT (the indoor vs outdoor distinction
changes the equation and the health interpretation).
title: Indoor or Outdoor Regime
examples:
- value: outdoor
from_schema: https://w3id.org/linkml/microschemas/envar
see_also:
- https://www.iso.org/standard/67188.html
- https://en.wikipedia.org/wiki/Wet-bulb_globe_temperature
rank: 1000
domain_of:
- DerivedHeatMetric
range: IndoorOutdoorEnum