Slot: Wind Speed Measurement Height (Metres) (wind_speed_measurement_height_m)
For WBGT and UTCI inputs, the wind-speed measurement height in metres. The ISO 7243 standard is 2 m, but reanalysis products often supply 10 m -- the height affects the WBGT value.
Tier: recommended
Why this slot matters
ISO 7243 assumes wind measured at 2 m, but reanalysis products usually supply 10 m wind; wind is slower near the ground, so an uncorrected 10 m input systematically shifts the resulting WBGT.
In plain terms
Wind blows faster the higher above the ground you measure it, so a "wind speed" is only meaningful together with the height it was taken at — this field records that height.
URI: envar:slot/wind_speed_measurement_height_m
Applicable Classes
| Name |
Description |
Modifies Slot |
| DerivedHeatMetric |
Methodology slots specific to derived heat metrics (WBGT, Heat Index, UTCI, a... |
no |
Properties
Type and Range
Cardinality and Requirements
Examples
See Also
Annotations
| property |
value |
| tier |
recommended |
| justification |
ISO 7243 assumes wind measured at 2 m, but reanalysis products usually supply 10 m wind; wind is slower near the ground, so an uncorrected 10 m input systematically shifts the resulting WBGT. |
| explanation |
Wind blows faster the higher above the ground you measure it, so a "wind speed" is only meaningful together with the height it was taken at — this field records that height. |
| covered_by |
None |
Schema Source
Mappings
| Mapping Type |
Mapped Value |
| self |
envar:wind_speed_measurement_height_m |
| native |
envar:wind_speed_measurement_height_m |
LinkML Source
name: wind_speed_measurement_height_m
annotations:
tier:
tag: tier
value: recommended
justification:
tag: justification
value: ISO 7243 assumes wind measured at 2 m, but reanalysis products usually
supply 10 m wind; wind is slower near the ground, so an uncorrected 10 m input
systematically shifts the resulting WBGT.
explanation:
tag: explanation
value: Wind blows faster the higher above the ground you measure it, so a "wind
speed" is only meaningful together with the height it was taken at — this field
records that height.
covered_by:
tag: covered_by
annotations:
omop_gaia:
tag: omop_gaia
annotations:
extent:
tag: extent
value: absent
status:
tag: status
value: asserted
where:
tag: where
value: no column
note:
tag: note
value: Tmax scenario carries no WBGT/UTCI inputs, so no wind-measurement
height.
degauss:
tag: degauss
annotations:
extent:
tag: extent
value: absent
status:
tag: status
value: asserted
where:
tag: where
value: no column
note:
tag: note
value: No WBGT/UTCI methodology, so no wind-measurement height.
amadeus:
tag: amadeus
annotations:
extent:
tag: extent
value: absent
status:
tag: status
value: asserted
where:
tag: where
value: no column
note:
tag: note
value: No WBGT/UTCI methodology, so no wind-measurement height.
cher:
tag: cher
annotations:
extent:
tag: extent
value: absent
status:
tag: status
value: asserted
where:
tag: where
value: no column
note:
tag: note
value: C-HER models no WBGT/UTCI heat metrics.
codata:
tag: codata
annotations:
extent:
tag: extent
value: out_of_layer
status:
tag: status
value: asserted
where:
tag: where
value: no column
note:
tag: note
value: WBGT wind-height metadata is instance-layer; out of scope for CODATA.
description: For WBGT and UTCI inputs, the wind-speed measurement height in metres.
The ISO 7243 standard is 2 m, but reanalysis products often supply 10 m -- the height
affects the WBGT value.
title: Wind Speed Measurement Height (Metres)
examples:
- value: '10'
description: ERA5 10 m wind used without height adjustment
from_schema: https://w3id.org/linkml/microschemas/envar
see_also:
- https://www.iso.org/standard/67188.html
rank: 1000
domain_of:
- DerivedHeatMetric
range: float